PVC Coated Flexible GI Conduit

Public Relations: (+98) 901 484 04 00

PVC Coated Flexible GI Conduit

Flexible GI Conduit is used to protect wires and cables in construction. It is made of aluminum with a thin layer of PVC as a cover on its surface. Important features of this thin layer include high flexibility, good tensile strength, glossiness and polished surface of final product. Due to the fact that the main use of these flexible pipes is in the open space, it must have high resistance to UV rays, so they are mainly produced in white and black colors.

 

Product Name Flexible GI Conduit PVC Granule
Other Names Flexible Conduit Granule
Product Code GECFC-N (Natural)
Application Flexible Conduit Coating
Features
  • Production based on Global Standards
  • Production based on customer requested mechanical properties
Color Milky

Production capability in diverse colors according to customer request.

Packaging In 25 kg bags of transparent polyethylene and finally bags are packed on wooden pallets. The weight of the pallets is approximately 1250 kg. The package can be changed according to customer request.

Technical Data sheet

Product Code: GECFC-N

Application: Wire & Cable – PVC Coated Flexible GI Conduit

Color: Milky (Colorless/Natural)

Form: Granule

Packaging: 25 KG PE Bag / Palletized

Storage: Dry place, away from sun shine and temperature lower than 30°C

Properties Test Method Units Typical Value
Type BS 6746 TI1
Tensile strength ASTM-D638 N/mm² 13.2±0.5
Elongation at break ASTM-D638 % 280±10
Gravity ASTM-D1895 G/CM^3 1.28±0.03
Hardness ASTM-D2240 Shore A 78±2
Thermal stability at 200°C ASTM-D749 MIN 62
Operating Temperature °C 70
Properties after aging 7 days at 100°C
Tensile strength ASTM-D638 N/mm² 12.2±0.5
Elongation at break ASTM-D638 % 260±10

Processing Conditions:

The following temperature profile is recommended as a guide line.

Barrel Temperature: (±10 °C)
Zone 1 Zone 2 Zone 3 Zone 4
150 155 165 170


These data, which are based on test results of major sample lots, are believed to be reliable. However, due to variation in ways of handling by consumers, recommendations are made without guarantee. These data are to be served only as a guide. The user must, by test or otherwise, determine suitability for this purpose. Our standard term and conditions of sale apply exclusively to all orders. No one is authorized by us to make oral warranties. We reserve the right to make changes without notice or obligation in our products and publications.