Fixed Installation insulation

Fixed Installation insulation

Fixed installation insulation granules are used to produce the first polymer coating in contact with the conductor. Insulation is more exposed to heat and damage due to high temperatures than other polymer coatings used in cable. Insulations are made of PVC and must have certain mechanical and thermal properties in accordance with IEC60502 standard.

Its density is between 1.40 to 1.45 (g / cm³). The granules used to produce fixed installation insulation are usually colorless and are used as insulation for light cables, single and multi stranded wires.

 

Product Name Fixed Installation Insulation Granules
Other Names PVC granules for Fixed Insulation
Product Code GEAN-N (Natural)
Application Conductor insulation for cable
Features
  • Production based on Global Standards
  • Production based on customer requested mechanical properties
Color Natural, Milky

Production capability in diverse colors according to customer request.

Packaging In 25 kg bags of transparent polyethylene and finally bags are packed on wooden pallets. The weight of the pallets is approximately 1250 kg. The package can be changed according to customer request.

Technical Data sheet

Product Code: GEAN-N

Application: Wire & Cable – Fixed Installation Insulation

Color: Milky (Colorless/Natural)

Form: Granule

Packaging: 25 KG PE Bag / Palletized

Storage: Dry place, away from sun shine and temperature lower than 30°C

Properties Test Method Units Typical Value
Type BS 6746 TI1
Tensile strength ASTM-D638 N/mm² 16.5±0.5
Elongation at break ASTM-D638 % 240±10
Gravity ASTM-D1895 G/CM^3 1.44±0.03
Hardness ASTM-D2240 Shore A 86±2
Thermal stability at 200°C ASTM-D749 MIN 62
Operating Temperature °C 70
Properties after aging 7 days at 100°C
Tensile strength ASTM-D638 N/mm² 17±0.5
Elongation at break ASTM-D638 % 225±10

Processing Conditions:

The following temperature profile is recommended as a guide line

Barrel Temperature: (±10 °C)
Zone 1 Zone 2 Zone 3 Zone 4
165 170 175 180


These data, which are based on test results of major sample lots, are believed to be reliable. However, due to variation in ways of handling by consumers, recommendations are made without guarantee. These data are to be served only as a guide. The user must, by test or otherwise, determine suitability for this purpose. Our standard term and conditions of sale apply exclusively to all orders. No one is authorized by us to make oral warranties. We reserve the right to make changes without notice or obligation in our products and publications.